Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
588firmware [2018/10/31 17:39]
n5na
588firmware [2018/10/31 17:44]
n5na
Line 267: Line 267:
   *Improve AN/​NR/​NB/​NCH/​RXEQU interaction/​loading.   *Improve AN/​NR/​NB/​NCH/​RXEQU interaction/​loading.
   *Add TRIP GAIN Adjustment for remote transmits. ​ (Requires One Plug version 1.0.8 to utilize.)   *Add TRIP GAIN Adjustment for remote transmits. ​ (Requires One Plug version 1.0.8 to utilize.)
 +
 +==== Version 1.027 ====
 +  *Changes that affect both Remote Mode and Radio Modes:
 +  *Improve transmit audio performance in FM mode.
 +  ***Changes that affect Remote Mode only:**
 +  *Increased Ethernet Handling priority in Remote Mode.
 +  *Modified the Remote Mode displayed FAIL counter to include
 +    *1 = Number of Receive Overruns detected by the Network IC (NIC).
 +      *Shows up as the lower three digits of the FAIL counter.
 +    *2 = Number of Network Chip Status Failures reported by the NIC.
 +      *Shows up as the top four digits of the FAIL counter.
 +  *For either of the two failures, the firmware performs a fast hardware reset of the network chip which takes less than 10 ms before it is back to streaming audio again. Solutions could include getting a better router, cleaning up network cables, providing proper RFI and EMI protection on all cabling, etc. If Either of these conditions persist, then they will result in very poor remote receive and transmit audio performance of the OMNI-VII. The firmware performs a hardware reset of the Network IC. This process takes 10ms before audio is back up and streaming. Solutions could include getting a better router, cleaning up network cables, providing proper RFI and EMI protection, etc.
 +  *Menu entrance / exit clears the Network Receive Overrun counter.
 +  *Menu entrance / exit clears the Network Chip Status Failure counter.
 +  *Removed the SMeter and Transmit power / SWR from the front panel display. Improves network packet reception and handling.
 +  *Removed the update of the various counters in remote mode while transmit is active.
 +  *Modified the TRIP data input buffer error handling algorithm.
 +  *Increased the “no communications timeout” for turning RIP Off automatically to 2 minutes.
 +    *RIP is turned off if the heartbeat command from the PC is not sent to the rig on a regular basis.
 +    *On networks with 95% of the 10Mb bandwidth loaded the OMNI-VII will sporadically missed the RIP OFF command.
 +
 +==== Version 1.028 ====