+ | **Comments by email from I1OWT/5 - June 10, 2007** | ||
+ | |||
+ | I had to adjust the pbt of omni V tranceiver and i could not adjust the pbt with the test point indicated by Antony. | ||
+ | |||
+ | The difference from the procedure described by Anthony, NT4X, is in the test point. It's possible that my frequency counter is not enough sensitive. | ||
+ | |||
+ | This is the procedure I used To adjust the PBT freq: | ||
+ | |||
+ | -Connect a frequency counter to L-3 on the PBT bd. | ||
+ | -Turn the PBT control full CW and adjust C-22 to 15.302.300 | ||
+ | -Turn PBT control to 12 o'clock position and adjust R-18 to read 15.300.000 | ||
+ | |||
+ | 73 de I1OWT/5 | ||
+ | |||
+ | pietro |