Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
416 [2007/02/11 21:44]
n5na created
416 [2018/11/01 02:53] (current)
n5na [Related Links]
Line 1: Line 1:
 ====== Titan II Model 416 ====== ====== Titan II Model 416 ======
 +
 +{{titan.jpg?​165|Front Panel}}{{titantank.jpg?​145|RF Deck}}{{titanbot.jpg?​120|Bottom}}{{titantube.jpg?​120|4CX1600B}}{{416rear.jpg?​190|}}
 +
 +
 +===== Reviews =====
 +  *[[http://​www.arrl.org/​members-only/​prodrev/​pdf/​pr0109.pdf|ARRL]] (Must be an ARRL member and logged in to view.)
 +  *[[http://​www.eham.net/​reviews/​detail/​213|eHam]]
 +  *[[http://​www.hamradiomarket.com/​Articles/​TenTecTitan%20II.htm|Bob Hutchinson, N5CNN]]
 +
 +
 +===== Related Links =====
 +  *[[this>​./​webarchive/​416|Archived Ten-Tec Web Page]]
 +
 +===== Mods =====
 +  *[[416fan|Fan Mod]]
  
 ===== Specifications ===== ===== Specifications =====
Line 5: Line 20:
   ***Band Coverage:** 160, 80, 40, 30, 20, 17 and 15 meters (12 and 10 meters for authorized users)   ***Band Coverage:** 160, 80, 40, 30, 20, 17 and 15 meters (12 and 10 meters for authorized users)
  
-**Power Output:** 1500 watts continuous in SSB, CW, AMTOR/​PACTOR (50 % duty cycle modes). 1500 watts RTTY/SSTV for up to 30 minutes (100% duty cycle modes). 1000 watts continuous key down.+  ***Power Output:** 1500 watts continuous in SSB, CW, AMTOR/​PACTOR (50 % duty cycle modes). 1500 watts RTTY/SSTV for up to 30 minutes (100% duty cycle modes). 1000 watts continuous key down
 + 
 +  ***Bold Text**Drive Power: 80 watts typical for 1500 watts output. 
 + 
 +  ***Tube:** Svetlana 4CX1600B ceramic tetrode.
  
-**Bold Text**Drive Power80 watts typical for 1500 watts output.+  ​***Plate Voltage Supply:** Step-start inrush protected. 3000 VDC at no load, 2700 VDC at full load. 6 amp; 1000 PIV matched diodes in full wave bridge. Filtered by 9 each 450 VDC 220 uF electrolytic capacitors. 10 ohm arc absorption resistor.
  
-**Tube:** Svetlana 4CX1600B ceramic tetrode.+  ​***Efficiency:** Up to 65% depending on band, frequency, line voltage, and load impedance.
  
-**Plate Voltage Supply:** Step-start inrush protected. 3000 VDC at no load, 2700 VDC at full load. 6 amp; 1000 PIV matched diodes in full wave bridge. Filtered by 9 each 450 VDC 220 uF electrolytic capacitors. 10 ohm arc absorption resistor.+  ​***Input/​Output impedances:** 50 ohms unbalanced with VSWR <2:1.
  
-**Efficiency:** Up to 65% depending on band, frequency, line voltage, and load impedance.+  ​***Harmonic Suppression:** Meets or exceeds FCC requirements.
  
-**Input/​Output impedances:** 50 ohms unbalanced ​with VSWR <2:1.+  ​***Full Break-in:** Built-in ​with T/R switching of less than 7 milliseconds.
  
-**Harmonic Suppression:** Meets or exceeds FCC requirements.+  ​***Protective Circuits:** A) Screen grid current regulation, over voltage protection and metal-oxide varistor arc-over protection. LED overdrive indication. B) Control grid current regulation, over-current limiting, LED overdrive indication. C) Plate current overdrive trip at 1.6A, series resistor for arc absorption.
  
-**Full Break-in:** Built-in with T/R switching of less than 7 milliseconds.+  ​***Primary Power:** 240 VAC@20 amps, 50/60 Hz.
  
-**Protective Circuits:** A) Screen grid current regulationover voltage protection ​and metal-oxide varistor arc-over ​protection. LED overdrive indication. B) Control grid current regulation, over-current limiting, LED overdrive indication. C) Plate current overdrive trip at 1.6A, series resistor for arc absorption.+  ​***Line Protection:** Primary line fuses, chassis interlock, and step-start inrush ​protection.
  
-**Primary Power:** 240 VAC@20 amps50/60 Hz.+  ​***Cooling:** Duct forced air, vertical exhaustcentrifugal blower.
  
-**Line Protection:** Primary line fuseschassis interlock, and step-start inrush protection.+  ​***Metering:** Plate current, screen grid currentplate voltageforward ​and reverse power. Peak foward power indicated on LED bargraph.
  
-**Cooling:** Duct forced airvertical exhaustcentrifugal blower.+  ​***Front Panel Controls:** TUNE and LOAD controls, band switch, standby/​operate,​ QSK/PTT, meter switch for screen grid current, plate voltageforward or reverse powerpower on/off.
  
-**Metering:** Plate current, screen grid current, plate voltage, forward ​and reverse powerPeak foward power indicated on LED bargraph.+  ​***Construction:** .125" aluminum tank and transformer chassis, ​.062" aluminum control chassis and covers.
  
-**Front Panel Controls:** TUNE and LOAD controls, band switch, standby/​operate,​ QSK/PTT, meter switch for screen grid current, plate voltage, forward or reverse power, power on/off.+  ​***Size:** HWD 8.2" x 17" x 19"
  
-**Construction:** .125" aluminum tank and transformer chassis, ​.062" aluminum control chassis and covers.+  ​***Weight:** 81 lbs(36.8 kg).
  
-**Size:** HWD 8.2" x 17" x 19" 
  
-**Weight:** 81 lbs. (36.8 kg). 
  

QR Code
QR Code 416 (generated for current page)