====== Orion Internal Power Adjustment ====== **From the Ten-Tec Reflector October 9, 2006** There are three adjustments on A5 board (under speaker): *R20 marked "PWR" calibrates forward power measurement *R21 marked "REF" calibrates reflected power measurement *R179 marked "ALC SET" calibrates actual output power Adjusting R179: *connect external power meter and dummy load; *set TX power to 100 W using MULTI knob; *press TUNE, then PWR and adjust "ALC SET" for 100 W on the external power meter. According to the schematics, A5 board is the same as on original Orion. 73, Sinisa YT1NT, VE3EA ===== July 17th 2021 ===== The information regarding potentiometer R20 is not correct. R20 is actually used to set the AM carrier level output. A side effect is that it influences the power indicator. Regards Onno pa1ap