Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
563inrad [2007/12/25 04:56] n5na |
563inrad [2015/03/17 16:20] n1eu |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Inrad Omni VI / VI+ Roofing Filter Mod ====== | + | ====== Inrad Omni VI / VI+ Roofing Filter Mod and Noise Blanker ====== |
*[[http://www.inrad.net/product.php?productid=210&cat=2&page=1|Inrad Omni VI / VI+ Roofing Filter Mod Page]] | *[[http://www.inrad.net/product.php?productid=210&cat=2&page=1|Inrad Omni VI / VI+ Roofing Filter Mod Page]] | ||
Line 59: | Line 59: | ||
Dave, K1FK | Dave, K1FK | ||
+ | |||
+ | August 29, 2008 | ||
+ | |||
+ | It's also simple to control the Inrad filter with the ATTN switch if you don't use that function. | ||
+ | Here's what you do: | ||
+ | Skip Inrad's instructions numbered 18 through 24. | ||
+ | Set aside the cable/connector provided for J4 on the Inrad board, you | ||
+ | won't need it. | ||
+ | Take the cable/connector provided for J3 and tie the lines together, | ||
+ | then | ||
+ | add an extension so the wire will reach up to the front of the Omni, | ||
+ | plus 4 or 5". | ||
+ | Locate the 3 pin white connector labeled 18, at the left front side of | ||
+ | the Front End Board, as viewed | ||
+ | from the front of the Omni. Cut the middle wire going to the connector, | ||
+ | leaving a few inches | ||
+ | behind on the connector in case you ever want to reconnect it. This is | ||
+ | the line that goes to the Attn | ||
+ | switch. Connect the lead from Inrad J3 to the end of the line going up | ||
+ | to the front panel Attn switch. | ||
+ | Tape up the end still attached to the connector. Set S1-S4 on the Inrad | ||
+ | board to ON. | ||
+ | |||
+ | That's all. Inrad now switches in and out with the Attn switch and the | ||
+ | led shows when Inrad is switched in. | ||
+ | All Omni filter switches are unaffected. | ||
+ | |||
+ | 73, Wayne K4ELO | ||