Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
240kw [2007/02/19 03:52]
n5na created
240kw [2007/05/21 00:41] (current)
Line 7: Line 7:
   *160 thru 10 meters @ 1.2:1 SWR   *160 thru 10 meters @ 1.2:1 SWR
   *2 meters @ 1.5:1 SWR   *2 meters @ 1.5:1 SWR
 +  *Load provided by two, 100 ohm 750 watt, ceramic resistors connected in parallel. ​ Specially designed resistors are chemically inert and temperature stable
   *Signal sample output   *Signal sample output
   *Over-temperature alarm   *Over-temperature alarm
   *Requires 12 VDC   *Requires 12 VDC
 +
 +===== Specifications =====
 +  ***Impedance:​** 50 ohms
 +  ***Typical VSWR:** 1.5 - 30 MHz = 1.2:1, 30 to 150 MHz = 1.5:1
 +  ***Power Ratings:**
 +
 +|  1500 watts  |  2:00 minutes ​ |
 +|  1000 watts  |  2:45 minutes ​ |
 +|  750 watts  |  4:30 minutes ​ |
 +|  500 watts  |  7:30 minutes ​ |
 +|  300 watts  |  continuous ​ |
 +
 +  ***RF Input Connector:​** SO-239, UHF type
 +  ***Fan and Alarm Power:** 10 - 14 VDC
 +  ***Size:** HWD 4.5" x 6" x 13" (11.5 x 15.25 x 33 cm)
 +  ***Weight:​** 6 lbs 6 oz (3 kg)

QR Code
QR Code 240kw (generated for current page)