+ | *Load provided by two, 100 ohm 750 watt, ceramic resistors connected in parallel. Specially designed resistors are chemically inert and temperature stable | ||
*Signal sample output | *Signal sample output | ||
*Over-temperature alarm | *Over-temperature alarm | ||
*Requires 12 VDC | *Requires 12 VDC | ||
+ | |||
+ | ===== Specifications ===== | ||
+ | ***Impedance:** 50 ohms | ||
+ | ***Typical VSWR:** 1.5 - 30 MHz = 1.2:1, 30 to 150 MHz = 1.5:1 | ||
+ | ***Power Ratings:** | ||
+ | |||
+ | | 1500 watts | 2:00 minutes | | ||
+ | | 1000 watts | 2:45 minutes | | ||
+ | | 750 watts | 4:30 minutes | | ||
+ | | 500 watts | 7:30 minutes | | ||
+ | | 300 watts | continuous | | ||
+ | |||
+ | ***RF Input Connector:** SO-239, UHF type | ||
+ | ***Fan and Alarm Power:** 10 - 14 VDC | ||
+ | ***Size:** HWD 4.5" x 6" x 13" (11.5 x 15.25 x 33 cm) | ||
+ | ***Weight:** 6 lbs 6 oz (3 kg) |