From the Ten-Tec Reflector July 28, 2006
FYI, ARRL used the optional Ten-Tec #2001 600 Hz filter for their tests per their normal policy of ordering any optional filters closest to their 500 Hz measurement bandwidth. Recall that ARRL did not use the TT #217 500 Hz for the original Orion tests due to IMD problems. Eventually this discovery led to the development of the Inrad #762 600 Hz, which in turn led to the 4-pole filters / front end scheme used in Orion II. Orion with an Inrad #762 is electrically quite similar to Orion II with the TT #2001.
RSGB never orders optional filters for their tests, so the stock 1000 Hz roofing filter was used in both Orion and Orion II tests. However they apparently had a bad 1000 Hz filter in their original Orion test since close-in IMD results using the 2400 Hz filter were better. The 2400 Hz results were the ones RSGB used in the review summary. This time around the 1000 Hz filter had better results for 1 kHz IMD spacing as expected.
Bottom line points to remember when comparing these product reviews:
73, Bill W4ZV